         Replacement of the Cartridge                                              1) Insert Hexagon wrench with 3mm width (TH-3L) into the
            Follow the instruction below to replace the Cartridge.                    Wedge Screw.

                                                 TH-3L
                                                 (Hexagon wrench with
                                                 3mm width)

         TH-3L                 Loosen     Wedge Screw  Cartridge                   2) Loosen the Wedge Screw.
         (Hexagon wrench with                Wedge                                 3) Remove the Wedge Screw and Wedge.
         3mm width)
                                                                                   4) Remove the Cartridge.

         Cartridge

                                          A state that the cam pin is              5) Before replacing the Cartridge, conrm that the Cam Pin is posi-
                                          positioned outwardly                        tioned radially-outwardly.

M

                                          A state that the cam pin is              6) If the Cam Pin is in the position shown in the left diagram, as-
                                          positioned inwardly                         sembling the Cartridge is not possible.

Milling

                               Wedge                                                7) Place the wedge so that its larger slant surface faces toward the
                                                                                       Cartridge.
         L-hand Thread
                                                                                    8) Turn the Wedge Screw two times to install the Wedge to the
                    Wedge Screw                                                        body.

         R-hand Thread           TH-3L    Turn 2 rotations to install on the body   9) When installing the Wedge Screw to the body, keep the Wedge
                                                                                       from rotating and screw it in.
         (Hexagon wrench with 3mm width)
                                                                                   10) Tighten the Wedge Screw by the torque of 5-6Nm.
                                                                                        Keep the Screw head and the Wedge even (prevent either of
                                                                                        those from sticking out)