Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Kyocera - Каталог фрезерование 2017 ENG

                                                                                       для заказа - kyocera@kyocera-tools.ru

               MSTC SLOT MILL (LAY-DOWN / HALF SIDE)

               Replacement of the Cartridge                                              (1) Insert Hexagon wrench with 3mm width (TH-3L) into the
                                                                                             Wedge Screw. TH-3L
               Follow the instructions below to replace the Cartridge.

                                                       TH-3L
                                                       (Hexagon wrench
                                                       with 3mm width)

                                                                                         (2) Loosen the Wedge Screw.
                                                                                         (3) Remove the Wedge Screw and Wedge.

               TH-3L              Loosen        Wedge Screw  Cartridge
               (Hexagon wrench                     Wedge
               with 3mm width)
                Cartridge                                                                (4) Remove the Cartridge.

                                                A state that the cam pin is              (5) Before replacing the Cartridge, make sure that the Cam Pin is
                                                positioned outwards                          positioned radially-outwards.

H  SLOT MILLS

                                                A state that the cam pin is              (6) If the Cam Pin is in the position shown in the left diagram,
                                                positioned inwards                          assembling the Cartridge is not possible.

               Left-hand Thread   Wedge                                                  (7) Place the wedge so that its larger slant surface faces toward
                                                                                             the Cartridge.
               Wedge Screw
                                                                                         (8) Turn the Wedge Screw two times to install the Wedge to the
               Right-hand Thread  TH-3L         Turn 2 rotations to install on the body      body.

               (Hexagon wrench with 3mm width)                                           (9) When installing the Wedge Screw to the body, keep the
                                                                                             Wedge from rotating and screw it in.

                                                                                         (10) Tighten the Wedge Screw by the torque of 5-6N·m.
                                                                                              Keep the Screw head and the Wedge even
                                                                                              (prevent either of those from sticking out).

   H26                                                       kyocera@kyocera-tools.ru
                                                                www.kyocera-tools.ru